Welcome to visit H&T Optoelectronic Co.,Ltd. Tel:86-755-86197637
 
产品分类
Products search
Keyword
Search
Din-rail Power Supply
Single Output Industrial DIN Rail Power Supply 20W
General AC input / full range
Protection function: short circuit / overload / overvoltage
Cooling by free air convection
Can be installed on DIN rail TS-35 / 7.5 or 15
Sol II
LED power indicator
100% full load burning test
1 years warranty
  • Description
  • Parameter
  • Application
  • Download
  • Related


5V 3A, 12V 1.67A, 15V 1.34A, 24V 1A Single Output Industrial DIN Rail Power Supply 20W 







SPECIFICATIONS

OUTPUT

Model

HT-MDR-20-5

HT-MDR-20-12

HT-MDR-20-15

HT-MDR-20-24

DC Voltage

5V

12V

15V

24V

Rated Current

3A

1.67A

1.34A

1A

Current Range

0-3A

0-1.67A

0-1.34A

0-1A

Rated Power

15W

20W

20W

24W

Ripple & Noise

80mVp-p

120mVp-p

120mVp-p

150mVp-p

Voltage Tolerance

±2%

±1%

±1%

±1%

Line regulation

±1.0%

±1.0%

±1.0%

±1.0%

Load regulation

±1.0%

±1.0%

±1.0%

±1.0%

Setup, Rise Time

500ms,30ms/230VAC   1000ms,30ms/115VAC at full load

Hold Up Time

50ms/230VAC   25ms/115VAC at full load

INPUT

Voltage Range

85-264VAC   47-63Hz; 120-370VDC

AC Current

0.55A/115VAC   0.35A/ 230VAC

Efficiency

76%

80%

81%

84%

Inrush Current

Cold start 20A/115V   40A/230V

Leakage Current

<1mA/240VAC

PROTECTION

Over Load

105% - 160% rated output power

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

5.75-6.75V

13.8-16.2V

17.25-20.25V

27.6-32.4V

Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

Working Temp., Humidity

-20~+70deg; 20%~90% RH non-condensing

Storage Temp., Humidity

-40~+85deg; 10%~95%RH

Temp. Coefficient

±0.03%/deg(0~50deg)

Vibration

10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P: 3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-F/G: 100M Ohms / 500VDC/25deg/70% RH

STANDARD

Safety Standard

Design refer to UL508,TUV EN60950-1

EMC Standard

Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1, EN61204-3, light industry level, criteria A

OTHERS

Dimension

22.5*90*100mm(W*H*D)

Weight

0.19Kg

Packing

72pcs/carton/14.7kg/0.91CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25deg of ambient temperature.

2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.

3.Tolerance: includes set up tolerance, line regulation and load regulation.

4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.