5V 10A, 12V 5A, 24V 2.5A, 48V 1.25A Industrial Din-rail Power Adpator
OUTPUT |
|
|||
Model |
HT-MDR-60-5 |
HT-MDR-60-12 |
HT-MDR-60-15 |
HT-MDR-60-24 |
DC Voltage |
5V |
12V |
15V |
24V |
Rated Current |
10A |
5A |
4A |
2.5A |
Current Range |
0-10A |
0-5A |
0-4A |
0-2.5A |
Rated Power |
50W |
60W |
60W |
60W |
Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
Voltage Adj. Range |
-5%,+10% |
-8%,+10% |
±10% |
±10% |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
Setup, Rise Time |
500ms,30ms/230VAC 200ms,30ms/115VAC at full load |
|||
Hold Up Time |
50ms/230VAC 20ms/115VAC at full load |
|||
|
|
|||
INPUT |
|
|||
Voltage Range |
88~264VAC 47~63Hz; 124~370VDC |
|||
AC Current |
1.8A/115V 1A/ 230V |
|||
Efficiency |
76% |
82% |
83% |
84% |
Inrush Current |
Cold start 18A/115V 36A/230V |
|||
Leakage Current |
<1mA/240VAC |
|||
|
|
|||
PROTECTION |
|
|||
Over Load |
105%~160% |
|||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
||||
Over Voltage |
115%~135% |
|||
Protection type: Shut down o/p voltage, re-power on to recover |
||||
|
|
|||
ENVIRONMENT |
|
|||
Working Temp., Humidity |
-20temp.~+60temp.; 20%~90%RH |
|||
Storage Temp., Humidity |
-40temp.~+85temp.; 10%~95%RH |
|||
Temp. Coefficient |
±0.03%/temp.(0~50temp.) |
|||
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|||
|
|
|||
SAFETY |
|
|||
Withstand Voltage |
I/P-O/P:3KVAC |
|||
Isolation Resistance |
I/P-O/P:100M Ohms / 500VDC |
|||
|
|
|||
STANDARD |
|
|||
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1,EN50178 |
|||
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3 |
|||
|
|
|||
OTHERS |
|
|||
Dimension |
40*90*100mm(L*W*H) |
|||
Weight |
0.33Kg |
|||
Packing |
60pcs/carton |
|||
|
|
|||
NOTE |
|
|||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 temp. of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |