144-cores outdoor fiber cross connect cabinet , SMC Cross-Connect Cabinet
HT2005-OCC-144 144-cores outdoor fiber cross connect cabinet is an outdoor optical access network in the trunk cable and wiring cable node to achieve outdoor fiber optic wiring equipment, you can realize the fiber optic through, disk storage, and fiber optic fusion splicing, scheduling functions. It can be installed outdoors on the ground and overhead in two ways.
Advantages:
Reliable fiber introduction, grounding and fixing; Swpa convenient; Suitable fiber integrated and optical fibers; A special suspension mechanism is designed to enable ground-mounted, wall-mounted, or aerial for users’ requirements.
N.W:14KGS
Material: Cold rolled sheets,stainless, SMC
Capacity: 48core, 72core, 96core, 144core
光交接箱安装流程
第一步:选址
第二步:底座的光缆管及预埋底框布置
第三步:混凝土底座的安装
第四步:交接箱体的安装
第五步:布放托盘
第六步:储存管理预置尾纤
第七步:外缆引入
第八步:外缆与尾纤熔接
第九步:开通路由。
光交接箱施工要点
(1)、光交接箱箱体必须安放平整、固定牢靠;
(2)、接地可靠,做好防腐、防锈、防酸处理;光交接箱地线统一用16mm*2的规格型号,铜鼻需用螺丝固定。
(3)、光交接箱底座瓷砖必须做到整齐规范;
(4)、光缆进线必须按照从左往右的顺序固定;加强芯从螺丝中心点起留10-15MM,胶带统一黑色,长短度一致;如遇不够固定,统一使用黑色扎带绑扎统一水平面,整齐一致,剪口朝内,剪平;
(5)、配线光缆在熔纤配线一体化模块中按照从下往上,从左往右的顺序进行熔纤施工;
(6)、过渡束管在熔纤配线一体化模块内不允许盘留超过半圈;过渡束管需弧度一致,所有的光纤过渡束管一起绑扎整齐;
(7)、光缆交接箱的光缆进线孔必须用防火泥封堵,封堵必须平整;做好光缆交接箱防水防尘,光缆挂牌挂在底座内 ;
(8)、熔纤配线一体化模块(熔纤盘)内,光纤过渡束管在熔纤配线一体化模块内必须用塑料小扎带固定
(9)、光交施工完毕,需清理施工现场、光交内卫生;防尘帽必须盖齐,颜色一致;
(10)、光交施工完毕后,光交面板标签必须在三天之内贴好,增补的成端位置必须在施工完毕后在面板标签注明位置;
(11)、光缆测试纤芯衰耗必须符合标准,不符合的必须当场整改、修复,必须进行对纤以保证光缆成端的正确性;
(12)、光交接箱中所开的光缆进线孔必须用防火泥进行封堵;
(13)、光缆余线不得盘放在光交接箱下面,必须抽回人(手)孔盘好后靠边固定(摆放)